Beijing is the capital of the great motherland. In order to improve the air environment and reduce air pollution, the municipal government put forward the air pollution control plan as early as 2000. Use of clean energy to replace coal-fired boilers in urban areas prohibits the construction of new coal-fired boilers. Water source heat pump air conditioning as a clean, energy saving, environmental protection technology quickly recognized and accepted. However, in the popularization and application of water source heat pump system, how to extract and recycle groundwater reasonably is the most important problem for users confused. In regions with relatively poor hydrogeological conditions, it is very difficult to recharge, with 100% recharge of groundwater difficult to achieve in some projects, resulting in instable system operation. Ground source heat pump air conditioning system just make up for the lack of water source heat pump system, it is through a closed PE heat exchange tubes and strata for heat exchange, heat pump to provide hot and cold sources, no longer need to extract and recharge groundwater. Its successful applications and demonstrations have made it possible to use geo-energy resources in areas with poor hydrogeological conditions. This article will compare the water source heat pump and ground source heat pump system, as well as their applicable geological conditions and regions, and through the introduction of introduction of ground source heat pump air conditioning system in the office of Greening Bureau of Chaoyang District, so that we further understand the ground source heat pump. First, the ground to heat pump system introduction 1, to summarize the human existence of the earth is rich in all kinds of mineral resources, while it is still a very huge energy resource base. Taking shallow ground surface as an example, the strata temperature of 5 to 10 meters below the surface of the earth does not change with the outdoor atmospheric temperature. It is maintained at 15 to 17 ° C throughout the year. This temperature is comparable to that of northern cities such as Beijing and it is a low-grade heat source available in winter, which is higher than the atmospheric temperature (5-15 ° C). In summer, it is lower than the atmospheric temperature (25-40 ° C) and is available Cold source. Ground energy heat pump system is the use of the characteristics of the winter's warm summer strata, by extracting and releasing the heat in the formation, to achieve winter heating and summer cooling. In winter, by inputting 1kW of electric energy, the heat pump unit can absorb 2.5 ~ 3kW of ground energy and provide 3.5 ~ 4kW of thermal energy for buildings. In summer, by inputting 1kW of electric energy, it can provide 3.5 ~ 4kW of cold energy for buildings. The key to the project's technical success is how to extract and release heat energy from the formation. Both water source heat pump and ground source heat pump belong to the category of ground heat pump, the difference is that they extract and release of energy in different ways. 2, water source heat pump and ground source heat pump 2.1 water source heat pump system water source heat pump is through the extraction of groundwater with the ground temperature, heat exchange between unit and groundwater, groundwater recharge through the recharge well into the formation. According to the amount of system load and water demand, the ability of the formation of water and recharge capacity to design the number of pumping wells and injection wells. Irrigation wells pumping can be a pumping, pumping more pumping or pumping more irrigation. 2.2 Ground Source Heat Pump System Ground source heat pump system by circulating heat in a closed loop heat transfer fluid and the formation between the heat absorption in winter, the summer heat. According to the size of the system load, thermal conductivity of the formation to design the form of heat exchange holes, the number and depth. Second, the Beijing hydrogeological conditions Beijing hydrogeological conditions are relatively good areas in the Yongdinghe ancient river, Chaobaihe ancient river, more suitable for the application of water source heat pump areas are: Haidian District, Shijingshan District, Fengtai District, North Daxing , Urban areas, Shunyi County, northeast and other parts of the county. According to the specific location of the hydrogeological conditions, its single-well pumping and recharging amounts are different. Ground-source heat pumps can be used in almost all areas, but the plains area such as northern Haidian, Chaoyang District, Changping District, southern Shunyi, Tongxian and Daxing southern areas are easy to construct, Lower; mountain and piedmont area, due to the formation of rock strata or larger particles, drilling costs are higher. Third, the conclusion Ground source heat pump system is clean, energy saving, economical and environmentally friendly technology, the use of a small amount of electricity to achieve heating and cooling. At the same time, the heat exchange hole system does not need to extract and recycle groundwater, and can also be utilized in areas with poor hydrogeological conditions. The promotion and application of ground source heat pump system will promote the implementation of "blue sky project" and occupy a place in the adjustment of energy structure.
Material: Q235 / Q345 / Carbon Steel / Ductile iron
Process: Forging / Investment Casting / Machining
Surface: Zinc / Chromium / Electro Plating / Dacormet / Painting
Unit Weight: 0.2-3KG
Looking for ideal 70mm 90mm 100mm 130mm Wing Nut Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Construction Formwork Accessories Wing Nut are quality guaranteed. We are China Origin Factory of Scaffolding Tie Rod Accessories Wing Nut. If you have any question, please feel free to contact us.
Casting Iron Plate Nut,Slope Plate Wing Nut,Casting Steel Anchor Nut,Scaffolding Slope Plate Nut
J.B MACHINERY (NINGBO) CO., LTD. , https://www.jbcastings.com