Maintenance of explosion-proof motor precautions

1. Explosion-proof motor shall not be disassembled; disassembly and maintenance, can not use the parts of the explosion-proof surface for the pry bar fulcrum, but also not allowed to beat or hit the explosion-proof surface.

2. Remove the motor, you should remove the hood, the fan, and then remove the end cap and the bearing cover plate wrench bolts, and then use round logs or copper rods along the axial impact axis, the end cover and the base apart , Finally remove the rotor. Demolition of parts, explosion-proof surface should be shelved upward, and covered with rubber or cloth liner, fastening bolts, spring pad, etc. Be careful not to lose.

3. Remove the motor, you should first remove the hood, fan, and then use the casing wrench to disassemble the end cap and bearing cap bolts, and then use round logs or copper rods along the axial impact axis, the end cap and the base apart , Finally remove the rotor. Demolition of parts, explosion-proof surface should be shelved upward, and covered with rubber or cloth liner, fastening bolts, spring pad, etc. Be careful not to lose.

4. If the explosion-proof surface damage, you must use lead-tin solder HISnPb58-2, 30% concentration of flux for hydrochloric acid (for steel parts) or 58-60% tin-zinc solder, solder flux of ammonium chloride 30% Zinc 70%, add water 100 ~ 150% of the mixed solution (cast iron) for welding, solder and the combination of parts to be solid, raised part to be polished to achieve the required finish.

5. In order to prevent rust on the explosion-proof surface, apply oil or 204-1 replacement anti-rust oil on the explosion-proof surface.