S&A chiller CW-6000 turned on but unelectrified

Today I will show you the troubleshooting regarding S&A chiller CW-6000 turned on but unelectrified

The fault cause as below
1. Power cord is not plugged in place
2. Fuse burnt-out
If the power plug is in poor contact, check the power interface
the power plug is plugged in place and in good contact
If fuse burnt-out
Please remove the sheet metal of S&A chiller
Open the electric box cover
Check the protective tube
Replace with spare one if necessary
Check and ensure whether the power supply voltage is stable
Check the power interface and power plug are in good contact
Reinstall the sheet metal of chiller
That is all.