Tuf-2000 Ultrasonic Water Flow Meter/Ultrasonic Transducer Flow Meter/Ultrasonic Heat Meter/GPRS, PSTN, Can, GSM Wireless Networking

Model NO.: Tuf-2000
Measuring Media: Liquid
Measuring Principle: Optics
Certification: JIS, DIN, ANS, GB, CE, UL, RoHS
LCD: Yes/No
Modle: Wall-Mount Ultrasonic Flow Meter
Medium: Liquid, Air, Gas
Ex-Proof: Intrinsic Safety/ Explosion-Proof
Signal: Pulse, 4~20mA, Hart, RS485
Trademark: U-ideal
Transport Package: Wooden Case or Carton
Specification: sgs
Origin: Tianjin, China
HS Code: 90261000
Ultrasonic flow meter is designed to measure the velocity of liquid within a closed conduit. It uses the well-known transit-time measurement principle, plus our proprietary signal processing and ultrasonic transceiving technologies.

Portable ultrasonic flow meter
Handheld ultrasonic flow meter
Separate fixed ultrasonic flow meter

Applicable medium:
Model: TUF - 2000 s Split type ultrasonic flowmeter is Used in various liquid volume flow online measurement, the host and sensor installation respectively: sensor installed on the pipeline, the host installed in indoor or instrument box, to use ultrasound special cable connects the host and sensor, currently is the most widely used ultrasonic flowmeter.
 
Special Features
 
Wide measuring range: choose different types of sensors, can realize caliber DN15 ~ DN6000mm pipe flow measurement
High reliability:  with low voltage, pulse transmission circuit, good accuracy, long service life and high reliability
Strong anti-jamming capability: double balance signal difference is the transmission and reception circuit; effectively resist strong interference sources such as inverter, television tower, and the high tension line
Powerful memory: automatic memory latest 512, 128 month, latest 10 years of accumulated heat and flow rate, accumulation of (date) (month) (year) data can be read through the MODBUS protocol
Heat measurement: with temperature sensor, can realize the heat measurement


Online function: GPRS,PSTN,CAN,GSM Wireless Networking

Tuf-2000 Ultrasonic Water Flow Meter/Ultrasonic Transducer Flow Meter/Ultrasonic Heat Meter/GPRS, PSTN, Can, GSM Wireless Networking
Sensor:
1.External clamp-on sensor (fluid temperature: ≤ 110 Degrees Celsius)
Standard small sensor S1 type (magnetic)
For diameter: DN15-100mm Dimension: 45 × 30 × 30mm
Quality: 75 grams
 
 
2.External clamp-on sensor (fluid temperature: ≤ 110 Degrees Celsius)
Standard M1-type medium-sized sensors (magnetic)
For diameter: DN50-700mm
Dimensions: 60 × 45 × 45mm
Quality: 250 g
 

 3.External clamp-on sensor (fluid temperature: ≤ 110 Degrees Celsius)
Standard large-scale sensor type L1
For diameter: DN300-6000mm
Dimensions: 80 × 70 × 55mm
Quality: 528 g


Hand-held type ultrasonic flowmeter
Tuf-2000 Ultrasonic Water Flow Meter/Ultrasonic Transducer Flow Meter/Ultrasonic Heat Meter/GPRS, PSTN, Can, GSM Wireless Networking
Tuf-2000 Ultrasonic Water Flow Meter/Ultrasonic Transducer Flow Meter/Ultrasonic Heat Meter/GPRS, PSTN, Can, GSM Wireless Networking




 
The specifications of our fixed ultrasonic flow meter
Measuring Principle Ultrasonic wave transmission time difference principle, dual CPU working in parallel, 4-byte floating-point operations
Accuracy Better than ±1.0 %
Repeatability 0.20%
Velocity 0.03- ±32 m/s
Measurement Period 0.5S
Display backlit LCD can display 2x20 letters instantaneous flow , cumulative flow, velocity, time, calories and other data signal output at the same time etc.
Keypad 4x4-key membrane keypad with tactile feedback
Input Can input two current signals (such as: temperature, pressure, liquid level, etc. signals) in order to achieve heat measurements or a dual-purpose machine
Output electric current signal 4-20mA or 0-20mA, etc. Impedance 0 - 1K, accuracy 0.1%
Isolated OCT output for frequency output (0-9,999Hz)
Internal Alarm (Buzzer) user programmable
External Alarm Driver alarm signal can be transmitted to Relay or OCT
output terminals to drive an externa alarm.
Data Interface RS-232 serial port .
Power AC: 220 V DC: 8~36VDC or AC7-30V
Power Consumption < 2W
Work time Continuous
Environment Temperature -30-80 Degrees Celsius
Environment Humidity 85% RH

Boiler Auxiliary Equipment

Soot Blower 001 JpgBoiler auxiliary equipment mainly includes water supply equipment, ventilation equipment, fuel supply, slag removal and dust removal equipment, steam and water pipes and accessories, detection instruments and automatic control equipment.



1. Water supply equipment


It is composed of water treatment equipment, water supply tank and feed pump 24. Water treatment equipment is used to remove impurities in water, such as oxygen, calcium and magnesium ions, to avoid scaling and corrosion on the inner wall of steam boiler, and to ensure the quality of boiler water supply. The treated boiler feed water is lifted by the feed water pump and then sent to the upper drum through the economizer.




2. Ventilation


The ventilation equipment includes air supply fan, induced draft fan and chimney. Its function is to provide air for mule fuel combustion and lead out combustion product flue gas from the boiler, so as to ensure the normal combustion, and make the flue gas wash the heating surface at the necessary flow rate of 7a68696466fe78988e69d8331333433626465 to strengthen heat transfer. Finally, the stack with a certain height will exhaust the smoke to the atmosphere to reduce the smoke pollution and improve environmental health.



3. Fuel supply, slag removal and dust removal equipment

This is for conveying fuel to boiler, removing ash and purifying flue gas. Belt conveyor, ash conveyor, ash truck and dust remover, etc. For boilers that need to be pre processed with fuel, fuel preparation such as screening, crushing and coal grinding shall also be included. In addition, the dust remover or flue gas desulfurization and denitrification device installed in the flue at the tail of the boiler is an indispensable auxiliary equipment to reduce the smoke pollution and protect the environment.




4. Check instruments and automatic control equipment


In addition to water level gauge, pressure gauge, safety valve and other instruments installed on the boiler body, in order to supervise, regulate and control the safe and economic normal operation of the boiler equipment, a series of instruments, automatic boiler feed water regulating device, automatic fuel combustion control device, etc. are often installed. Some boiler rooms are also equipped with industrial television and remote control device and even more modern automatic control system, more Scientific supervision. Control boiler operation.


Boiler auxiliary equipment, not every boiler is equipped completely, but with the boiler capacity, type, fuel characteristics and combustion mode as well as water quality characteristics and many other factors to adapt to local conditions, adapt to the times, more practical requirements and objective conditions.



Carbon Enamel Pipe,Steel Tubes For Boilers,Boiler Heating Element,Boiler Air Preheaters

Jinan Yuanda Power Equipment Co.,Ltd. , https://www.ydboilerpart.com